Skip to content

Blind quality monitoring

Blind quality monitoring checks that markers stay consistent through the main marking phase. Insights mixes monitoring scripts from Standardisation 1 into each marker's live scripts. Markers can't tell which they are. Insights compares their scores with the agreed ones, and can notify senior markers or suspend a marker who strays outside the tolerances.

This page covers setting up blind quality monitoring for a project. To follow how markers are doing, see Check blind quality monitoring.

Set up blind quality monitoring

The settings are in the project's Blind Quality Monitoring section, under Quality Controls. Select the pencil icon on the section to change them. You can choose how monitoring scripts are placed until the project starts marking.

  1. Choose Use monitoring scripts for blind quality monitoring.
  2. Choose whether to tick Recycle monitoring scripts. It's ticked by default. When a marker has scored every monitoring script for an item, it lets Insights give them ones they've already scored. Without it, they get no more monitoring scripts for that item.
  3. Choose how monitoring scripts are placed:
    • Randomly allocated — each script a marker gets has a set chance of being a monitoring script. Enter that chance as the Sample rate.
    • Round robin — a marker gets one monitoring script after every so many live scripts. Enter that number in Number of normal scripts per one monitoring script.
    • Stratified monitoring — monitoring scripts sit in a fixed pattern of stages and blocks for each item. See Stratified monitoring.
  4. For each item, enter the RMS Tolerance, the Absolute Tolerance above (+) and below (−) the agreed score, and the + and − tolerance for each marking scheme component, if the item has them. What you enter in the first item's row is copied to the rows below.
  5. Under Notification Settings, choose what happens when a marker's monitoring scores are out of tolerance:
    • Send the notification to SM's or KP's — emails the markers above them in the marking team. This is the default.
    • Suspend the marker — stops them marking until a senior marker reinstates them.
  6. Enter the No. of out-of-tolerance scripts before action is taken. With 2, the action happens on a marker's 2nd out-of-tolerance script, then the 4th, the 6th and so on. The default is 1.
  7. Select Save.

The info box at the top suggests a Sample rate of the item's monitoring scripts divided by the number of scripts each marker marks, times 100, and the same tolerances as Standardisation 3.

The Blind Quality Monitoring section being edited, with Use monitoring scripts for blind quality monitoring at badge 1, Recycle monitoring scripts ticked at badge 2, Randomly allocated at badge 3 with a Sample rate of 25%, and Round robin and Stratified monitoring below

The Tolerance Settings for Y9-WRIT-01, out of 12, and Y9-WRIT-02, out of 6: an RMS Tolerance of 1 and an Absolute Tolerance of plus and minus 1 for each item, and plus and minus 1 for each of Ideas, Language and Structure, with badge 4 on the first row

Notification Settings with Send the notification to SM's or KP's chosen at badge 5, No. of out-of-tolerance scripts before action is taken set to 2 at badge 6, and Save at badge 7

Stratified monitoring

Stratified monitoring splits each item's marking into stages, and each stage into blocks of scripts. You set how many live and monitoring scripts each block holds, then where in each block the monitoring scripts go. You can place them at random, choose specific scripts for specific positions, or both.

With Stratified monitoring chosen, the section has three tabs. 1. General holds the tolerances and notification settings described above. Select Next to move to the next tab, and Save on the last.

The Blind Quality Monitoring options with Stratified monitoring chosen and boxed, and the 1. General, 2. Stages & Blocks and 3. Stratified Sequence tabs below, the last two dimmed

Set the stages and blocks

On 2. Stages & Blocks, for each item:

  1. Enter the No. of Blocks in the stage, the No. of Live Scripts (in each BLOCK) and the No. of Monitoring Scripts (in each BLOCK). Total Scripts (Live + Monitoring) adds them up.
  2. To add another stage, select Add Stage. To remove one, select its remove icon under Actions.
  3. To give every item the first item's stages, select Copy.

The live scripts can't add up to more than the item's responses, and the monitoring scripts can't add up to more than its monitoring scripts in S1.

Stages & Blocks for Y9-WRIT-01: Stage 1 with 2 blocks of 3 live scripts and 1 monitoring script each, 6 + 2 in total, with badge 1 on the numbers, 2 on Add Stage and 3 on Copy, and Y9-WRIT-02 collapsed below

Place the monitoring scripts

On 3. Stratified Sequence, each item shows its stages and blocks as rows of cells. The Legend shows what each cell holds: a live script, a randomly allocated monitoring script, or a manually allocated one, which shows that script's score.

  1. Open the menu beside Generate All and choose its options:
    • Allocate monitoring scripts — places specific monitoring scripts, not just positions for them. It needs S1 sampling to have produced each item's monitoring scripts. If it hasn't, Insights says "There are currently insufficient monitoring scripts. Please complete Standardisation 1 Sampling, and try again."
    • Repeat sequence for all questions — gives every item the same pattern.
  2. Select Generate All to place monitoring scripts at random for every item.
  3. To do one item instead, select its Generate.
  4. To give every item the first item's sequence, select Copy.
  5. Change any cell you want. See Change a cell.

Hover over a cell to see what it holds.

The Stratified Sequence tab with the Generate All menu open, Allocate monitoring scripts ticked at badge 1 and Generate All at badge 2, the Legend, and Y9-WRIT-01's stage 1 in two blocks of four cells: a manually allocated monitoring script scoring 8 in block 1 and a randomly allocated one in block 2. Generate is at badge 3 and Copy at badge 4

Change a cell

Select a cell to open the Stratified Sequence window. Which options it offers depends on what the cell holds:

Option Live script Randomly allocated Manually allocated
Change the position of this monitoring script. Yes Yes
Allocate a random monitoring script at this position. Yes Yes
View the monitoring script allocated at this position. Yes
Allocate a specific monitoring script at this position. Yes Yes
Remove this monitoring script allocation. Yes Yes

Choose an option, then select Continue, or Remove if you're removing the allocation.

  • Change the position — enter the new Stage, Block and Index, then select Save.
  • Allocate a random monitoring script — makes the cell a randomly allocated monitoring script.
  • View the monitoring script — shows the script and its agreed scores.
  • Allocate a specific monitoring script — use the arrows to find the script you want, then select Allocate. The cell becomes a manually allocated monitoring script.
  • Remove this monitoring script allocation — makes the cell a live script.

The Stratified Sequence window for a manually allocated cell, listing Change the position of this monitoring script, Allocate a random monitoring script at this position, View the monitoring script allocated at this position and Remove this monitoring script allocation, with Continue boxed

The position page of the Stratified Sequence window, with Stage 1, Block 2 and Index 3, and Save boxed

Settings

Administrators can configure these settings at Marking > Marking Extended Settings. See Marking settings.

Enable Blind Quality Monitoring, in Marking Project Settings — makes blind quality monitoring available to marking projects. On by default.

Enable Per Mark Scheme Component Tolerance For Monitoring Script, in Marking Project Settings — adds a tolerance for each marking scheme component to the monitoring settings. On by default.

Permission to change a project's blind quality monitoring settings is set per role at Settings > Roles.